Products

YOKOGAWA

Yokogawa’s Portable and Handheld Instruments offer a broad range of portable test equipment to fulfill numerous short-term or continuous measurement application requirements. Included in our wide range of products are: Calibrators, DMM, Clamp-on Testers, Portable Power Monitors, Portable Data Loggers, Insulation Testers, Thermometers, Portable Analog meters, Light Meters, Precision Measuring equipment, and more.

  • Filter
  Name SKU Description Category
YOKOGAWA 100:1 PROBE 701945 Passive Probe, 1000Vrms, 250MHz, 100:1, 50MΩ, 3.0m, 'Mini' with extra-long 3m lead.  Compatible with DL1700, DLM2000, DLM4000, DL/DLM6000, DL9000 and SB5000.  See also 701944 for 400 MHz version of this same probe. VOLTAGE PROBES
YOKOGAWA 100:1 ISOLATED PROBE 701947 Passive Probe, 3540Vp-CAT I, 1000Vp-CAT II, 200MHz, 100:1, 100MΩ, 1.5m, 'Isolated Probe'  'Iso-Probe'.  For use with 701250, 701251, 701260, 701280, 701281, 720210 isolated-input modules ONLY.  For use with DL850 series, DL750/DL750P, SL1400, and SL1000.  Not for use with CAT III or CAT IV measurements VOLTAGE PROBES
YOKOGAWA PBA1000 1.0 GHZ ACTIVE PROBE Use this 10:1 active probe with the DL6054,  DLM6054, DL9040/DL9040L , DL9505L/DL9705L,  DLM2052/DLM2054 series to realize system measurements up to 500 MHz BW. VOLTAGE PROBES
YOKOGAWA PBA1500 (701914) 1.5 GHZ ACTIVE PROBE Use this 10:1 active probe with the DL6104, DLM6104, DL9140/DL9140L , DL9510L/DL9710L, SB5000 series to realize system measurements up to 1.0 GHz BW. VOLTAGE PROBES
YOKOGAWA PBA2500 (701913) 2.5 GHZ ACTIVE PROBE Use this 10:1 active probe with the DL6154, DL9240 series to realize system measurements up to 1.5 GHz BW. VOLTAGE PROBES
YOKOGAWA PBL5000 (701974) 5 GHZ LOW CAPACITANCE PROBE The PBL5000 low-capacitance "transmission line" probe (passive) features both 10:1 and 20:1 attenuation.This probe requires a 50 Ω scope/termination and can be used with any oscillscope with a BNC input. The change in attenuation is realized by changing resistance on the tip of the probe; Can also be used with DC Block 701975. For use with a scope which does not have a built-in 50 Ω termination, please purchase a 700976 50 Ω external (BNC) pass-thru terminator. VOLTAGE PROBES
YOKOGAWA 10 MHZ PASSIVE PROBE 701940 Passive Probe, 600Vpeak, 6MHz/10MHz, 1:1, 10:1, 1MΩ/10MΩ, 1.5m '600V Non-Isolated' Typically used for non-isolated ScopeCorder module 701255 on the Dl850/DL850V/DL750/DL750P/SL1400/SL1000. VOLTAGE PROBES
YOKOGAWA 200 MHZ PASSIVE PROBE 700960 Passive Probe, 600Vp, 200MHz, 1:1 & 10:1 switcable, 1MΩ/10MΩ, 1.5m,This is the standard passive probe included with a DL1600. VOLTAGE PROBES
YOKOGAWA PB500 500 MHZ PASSIVE PROBE (701943) Passive Probe, 'PB500', 600Vp, 500MHz, 10:1, 10MΩ, 1.5mSupplied standard with DL9000/SB5000. VOLTAGE PROBES
YOKOGAWA 900 MHZ FET PROBE 700939 Active Probe, 10Vp, 900MHz, 10:1, 2.5MΩ / 1.8pF, 1.5m, FET Probe w/ LEMO power pig-tail See Also: 700938-3-D Active Probe Power Supply w/ 2 LEMO output jacks701934-D Active Probe Power Supply w/ 4 LEMO output jacksPlease use a 50Ω input oscillosope scope or use 700976 pass-thru terminator. VOLTAGE PROBES
YOKOGAWA CURRENT PROBE 100 MHZ/30 ARMS 701928 Frequency bandwidth: DC to 100 MHzMaximum continuous input range: 30 Arms Functions with DLM2000, DLM4000, DL/DLM6000, DL/DLM9000 and SB5000. CURRENT PROBES
YOKOGAWA CURRENT PROBE 50 MHZ/30 ARMS 701929 Frequency bandwidth: DC to 50 MHzMaximum continuous input range: 30 ArmsFunctions with DLM2000, DLM4000, DL/DLM6000, DL/DLM9000 and SB5000. CURRENT PROBES
YOKOGAWA CURRENT PROBE 10 MHZ/150 ARMS 701930 Frequency bandwidth:  DC to 10 MHz Maximum continuous input range: 150 Arms Functions with Digital Oscilloscopes, Scopecorders or other waveform measuring instruments. CURRENT PROBES
YOKOGAWA CURRENT PROBE 2 MHZ/500 ARMS 701931 Frequency bandwidth:  DC to 2 MHz Maximum continuous input range: 500 Arms Functions with Digital Oscilloscopes, Scopecorders and other waveform measuring instruments. CURRENT PROBES
YOKOGAWA CURRENT PROBE 100 MHZ/30 ARMS 701932 Frequency bandwidth:  DC to 100 MHz Maximum continuous input range: 30 Arms Functions with Digital Oscilloscopes, Scopecorders or other waveform measuring instruments. CURRENT PROBES
YOKOGAWA CURRENT PROBE 50 MHZ/30 ARMS 701933 Frequency bandwidth:  DC to 50 MHz Maximum continuous input range: 30 Arms Functions with Digital Oscilloscopes, Scopecorders or other waveform measuring instruments. CURRENT PROBES
YOKOGAWA SOFT CARRYING CASE FOR DL750P AND SL1400 701967 Three pockets are provided for storing accessories and the user’s manual OSCILLOSCOPE ACCESSORIES
YOKOGAWA PLUG ON CLIP 701948 Connected to the 700929, 701947Maximum input voltage: 1,000V (DC + ACpeak)Length: 0.26m/0.3m/0.4mApplicable for DL750/DL750P, SL1000, SL1400 OSCILLOSCOPE ACCESSORIES
YOKOGAWA 50 Ω TERMINATOR 700976 Used to connect an oscilloscope having a 1M-ohm input to a probe with a 50-ohm output. OSCILLOSCOPE ACCESSORIES
YOKOGAWA LONG TEST CLIP 701906 Set contains one black and one red clip1000 Vrms-CAT II2 pieces (red and black) in 1 set Connected to the 758933, 758917, or 701901Length: 0.3mApplicable for DL750/DL750P, SL1000, SL1400 OSCILLOSCOPE ACCESSORIES