Fluke

  • Filter
  Name SKU Description Category
Fluke TPS FLEX 36-TF 3000A/6000A Thin Flex Flexible Current Probe with 36-inch Cable For the Fluke 1760 Power Recorder Measuring Range selectable per software: 30A to 3000A 60A to 6000A Peak current for sinusoidal currents: 10kA 19kA Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable Current Clamp DMM Accys
Fluke TPS FLEX 24-TF 200A/1000A Thin Flex Flexible Current Probe with 24-inch Cable For the Fluke 1760 Power Recorder Measuring Range selectable per software: 2A to 200A 10A to 1000A Peak current for sinusoidal currents: 480A 2700A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 600 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable Current Clamp DMM Accys
Fluke TPS FLEX 18-TF 100A/500A Thin Flex Flexible Current Probe with 18-inch Cable For the Fluke 1760 Power Recorder Measuring Range selectable per software: 1A to 100A 5A to 500A Peak current for sinusoidal currents: 240A 1350A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable Current Clamp DMM Accys
Fluke TPS CLAMP 50 A / 5 A Clip-on Current Transformer Measuring Range selectable per software 1 A to 100 A 5 A to 500 A Peak current for sinusoidal currents 240 A 1350 A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5 ° Jaw Opening 45 cm length 2 m cable Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts) Current Clamp DMM Accys
Fluke TPS CLAMP 200 A / 20 A Clip-on Current Transformer Measuring Range selectable per software:0.2 A to 20 A 2 A to 200 A Peak current for sinusoidal currents74 A 300 A Intrinsic error 0.5% Frequency Range 40 Hz to 10 kHz Operating Voltage 300 V CAT IV Phase Error 0.5 ° Jaw Opening < 15 mm diameter or 15 x 17 mm bus bars Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts) Current Clamp DMM Accys
Fluke TPS CLAMP 10 A / 1 A Clip-on Current Transformer Measuring Range selectable per software:0.01A to 1A0.1A to 10A Peak current for sinusoidal currents:3.7A to 37A Intrinsic error: 0.5% Frequency Range: 40Hz to 10kHz Operating Voltage: 300V CAT IV Phase Error: 0.5° Jaw Opening: <15mm diameter or 15x17mm bus bars Errors in % of measuring range at 23°C ± 2K; 74°F±2K, for 48 to 65Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts) Current Clamp DMM Accys
Fluke 3585R Split-Core Current Transformers Current range: 0.5 – 1-0A Accuracy: 1% RDG +/- 0.5% FS Frequency response: 5 kHz Length: 7/16” (1 cm) Current Clamp DMM Accys
Fluke 3584R Split-Core Current Transformers Current range: 0.1 – 40A Accuracy: 1% RDG +/- 0.5% FS Frequency response: 5 kHz Length: 7/16” (1 cm) Current Clamp DMM Accys
Fluke 3583R Split-Core Current Transformers Current range: 0.01 – 10A Accuracy: 1% RDG +/- 0.5% FS Frequency response: 5 kHz Length: 7/16” (1 cm) Current Clamp DMM Accys
Fluke 3212-PR-TF 5000A Flex Thin Flex Current Probe, 4 Feet Long For the Fluke 1750 Power Recorder The Fluke 3310-PR-TF 5000A Flex Thin Flex Current Probe  is an ac current probe utilizing the Rogowski principle. The Fluke 3310PRTF Probe is designed for use with the Fluke 1750 Power Recorder and measures current from very low frequencies up to the 50th harmonic of a 50/60 Hz power supply. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and around large conductors. Current Clamp DMM Accys
Fluke 3310-PR-TF 5000A Flex Thin Flex Current Probe, 2 Feet Long For the Fluke 1750 Power Recorder The Fluke 3310-PR-TF 5000A Flex Thin Flex Current Probe  is an ac current probe utilizing the Rogowski principle. The Fluke 3310PRTF Probe is designed for use with the Fluke 1750 Power Recorder and measures current from very low frequencies up to the 50th harmonic of a 50/60 Hz power supply. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and around large conductors. Current Clamp DMM Accys
Fluke 3300 Clamp-on Current Transformer Current range: 10-3000A Accuracy: 2% RDG +/- 0.05% FS Frequency response: 5 kHz Jaw opening: 3.5 x 4.5” dia. (9 x 11 cm) Current Clamp DMM Accys
Fluke 3210-PR-TF 1000A Flex Thin Flex Current Probe For the Fluke 1750 Power Recorder The Fluke 3210-PR-TF 1000A Flex Thin Flex Current Probe  is an ac current probe utilizing the Rogowski principle. The Fluke 3210PRTF Probe is designed for use with the Fluke 1750 Power Recorder and measures current from very low frequencies up to the 50th harmonic of a 50/60 Hz power supply. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and around large conductors. Current Clamp DMM Accys
Fluke 3120R Clamp-on Current Transformer Current range: 0.05-200A Accuracy: 1% RDG +/- 0.3% FS Frequency response: 5 kHz Jaw opening: .78” dia. (2 cm) Current Clamp DMM Accys
Fluke 3112RPM Flexi-CT™ Flexible Current Transformer Current range: 2-100 Accuracy: 1% RDG +/- 0.5% FS Frequency response: 7 kHz Length: 48” (1.2 cm) Current Clamp DMM Accys
Fluke 3100R Clamp-on Current Transformer Current range: 1-1000A Accuracy: 1% RDG +/- 0.05% FS Frequency response: 5 kHz Jaw opening: 2" dia. (5 cm) Current Clamp DMM Accys
Fluke 140S-PR Clamp-on Current Transformer Operates with the Fluke 1750 Power Recorder It supplies accurate nonintrusive measurement of ac current The probe has a current range from 0.05 A to 40 A The frequency range is 40 Hz to 5 kHz The clamp is approved for CAT III 600 V Current Clamp DMM Accys
Fluke i800 AC Current Clamp Probe Measures AC current from 100mA to 800 A rms 30 Hz to 10 kHz frequency range CAT III 600 V rating Accepts up to 54 mm (2.1 in) diameter conductor size 1000:1 conversion factor for easy calculation Rugged positive action design Current Clamp DMM Accys
Fluke i6000s Flex-36 AC Current Clamp (36in.) The i6000sflex is an AC current probe utilizing the Rogowski principle It can be used to measure currents up to 6000A when used in conjunction with oscilloscopes, recorders or data loggers The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas Current Ranges: 60A/600A/6000A AC RMS Output Sensitivity (AC coupled): 50 mV /5mV / 0.5mV per A Frequency Range: 10 Hz to 50 kHz (- 3 dB) Load Impedance: 100 kOhm minimum Accuracy (at +25°C): ±1%... Current Clamp DMM Accys
Fluke i6000s Flex-24 AC Current Clamp (24in.) The i6000sflex is an AC current probe utilizing the Rogowski principle It can be used to measure currents up to 6000A when used in conjunction with oscilloscopes, recorders or data loggers The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas Current Ranges: 60A/600A/6000A AC RMS Output Sensitivity (AC coupled): 50 mV /5mV / 0.5mV per A Frequency Range: 10 Hz to 50 kHz (- 3 dB) Load Impedance: 100 kOhm minimum Accuracy (at +25°C): ±1%... Current Clamp DMM Accys