TST4701-316-2 LEAKAGE DECTECTOR WITH BUILT-IN PUMP - GERMANY
|
|
electronic gas leak detector with flexible measurement probe, mains charger and earphones
Optical and audible alarm with bar display for increasing and dangerous gas concentrations
Integrated pump
Trend display shows maximum leakage
Flexible measurement probe for inaccessible places
Meas. range10 ppm to 4,0 Vol. % CH4 10 ppm to 1,9 Vol. % C3H8 10 ppm to 4,0 Vol. % H21st alarm limit200 ppm CH4 100 ppm C3H8 200 ppm H22nd alarm limit10.000 ppm CH4 5.000 ppm C3H8 10.000 ppm H2Battery... |
Gas Leak Detectors
|
|
|
|
TIM001C-DIGITAL ULTRASONIC THICKNESS GAUGE FOR METAL/NON-METAL MATERIALS-0.75MM~225.0MM-W SOFTWARE
|
|
Features
1.Capable of performing measurements on a wide range of material,
including metals, plastic, ceramics, composites, epoxies, glass and
other ultrasonic wave well-conductive materials.
2.Transducer models are available for special application, including for coarse grain material and high temperature applications.
3.Probe-Zero function, Sound-Veloctiy-Calibration function.
4.Two-Point Calibration function.
5.Coupling status Indicator showing the coupling status.
6.Battery... |
Metal/Non-metal thickness gauges (ultrasonic)
|
|
|
|
TMT109-HIGH PRECISION ULTRASONIC THICKNESS GAUGE(0.15mm – 20.0mm)
|
|
HIGH ACCURACY AND RESOLUTION UP TO 0.001mm or 0.0001 inch
MEASURING ULTRA THIN SAMPLE AS LOW AS 0.15mm or 0.006 inch
DISPLAY UNITS : IMPERIAL and METRIC
AUTOMATIC SELF CALIBRATION
COUPLANT INDICATOR
AUTOMATIC POWER OFF DEVICE
HIGH-LOW LIMIT ALARM
LCD BRIGHTNESS ADJUST
LOW BATTERY INDICTOR
TECHNICAL SPECIFICATIONS:
Measuring Range (for steel)
Interface-Echo Mode: (I-E or Standard Mode)
1.50mm – 20.0mm (0.059in – 0.787 in)
Echo-Echo Mode: (E-E or High... |
Metal/Non-metal thickness gauges (ultrasonic)
|
|
|
|
TMT102A-ADVANCED GRAPHICAL ULTRASONIC THICKNESS GAUGE (Live Color A-Scan +Time-based B-Scan + Through -paint function)
|
|
*Color OLED 320x240 Pixels Display
*Live Simultaneous Color A-Scan and Thickness Display
*Control of Gain, Blanking, Gate, Range, Delay, RF and Rectify Modes
*Time-based B-Scan Display
*Echo-Echo Mode,Thru Paint & Coatings |
Metal/Non-metal thickness gauges (ultrasonic)
|
|
|
|
TMT101A-ADVANCED GRAPHICAL ULTRASONIC THICKNESS GAUGE (A-SCAN SNAPSHOT + THROUGH -PAINT FUNCTION)
|
|
Color 320x240 Pixels Display A-Scan Snapshot
Echo-Echo Mode(Thru Paint & Coatings)
Stores 100,000 Readings Gain: Low, Medium or High for varying test conditions |
Metal/Non-metal thickness gauges (ultrasonic)
|
|
|
|
TIM001B-ENHANCED DIGITAL ULTRASONIC THICKNESS GAUGE FOR METAL/NON-METAL MATERIALS-0.75MM~225.0MM
|
|
1. Capable of performing measurements on a wide range of material, including metals, plastic, ceramics, composites, epoxies, glass and other ultrasonic wave well-conductive materials.
2. Transducer models are available for special application, including for coarse grain material and high temperature applications.
3. Probe-Zero function, Sound-Velocity-Calibration function.
4. Two-Point Calibration function.
5.Coupling status Indicator showing the coupling status.
6. Battery information... |
Metal/Non-metal thickness gauges (ultrasonic)
|
|
|
|
TIM006A-5MHz 8mm Probe Transducer Sensor for Ultrasonic Thickness Gauge Meter
|
|
Introduction:Name: Probe for Ultrasonic Thickness GaugeModel: PT-08 (Lemo 00 connector)Frequency: 5MHzDiameter of the contact proportion: 8mmMeasuring Range: 0.8mm-300.0mmAvaliable Contact Temperature: ﹣10ºC-60ºCApplicaiton: use for all Ultrasonic thickness gauge |
Metal/Non-metal thickness gauges (ultrasonic)
|
|
|
|
TIM001-TT100SV2 DIGITAL ULTRASONIC THICKNESS GAUGE FOR METALLIC/NON-METALLIC MATERIALS-1.20MM - 225.0MM
|
|
The TIM001is the most popular ultrasonic thickness gauge sold in Australia. It is a low cost, hand-held microprocessor controlled thickness gauge specifically designed for measuring the thickness of metallic and non-metallic materials e.g. aluminium, titanium, plastic, plastics, ceramics, glass and any other good ultrasonic wave-conductor as long as it has parallel top and bottom surfaces. |
Metal/Non-metal thickness gauges (ultrasonic)
|
|
|
|
TMT114-CROSS HATCH CUTTER
|
|
Specifications
H cross hatch cutter is applicable to determine the adhesion of organic coatings by cross-hatching.
This instrument is designed for assessing the resistance of paint or related coatings to separation from substrates when a right-angle lattice oattern is cut into the coating, penetrating through to the substrate. The Cross Hatch Cutters conform with the requirements of :BS 3900 E6;BS/EN ISO 2409;ASTM D 3359;GB/T 9286, ,it is economy. Main Technical Parameters: 1.Six working... |
CROSS HATCH CUTTER
|
|
|
|
TEN811-Large Wall Display Temperature/Humidity Monitor with 95dB Sound Alarm/Controller
|
|
- Complete environmental monitor and alarm - Wall-Mounted LED type, easy reading - Alarm set for Hi and Low limit-Temperature and Humidity - LED displays real time data |
Wall-display humidity meters
|
|
|
|
TST0467-622 HYGROMETER WITH PRESSURE DISPLAY, INCL. CALIBRATION PROTOCOL, BATTERIES
|
|
Precise measurement of temperature, humidity and pressure
All important values at a glance: current measurement values as well as date and time
Calibration and adjustment of the measuring instrument possible on site with the optional calibration and adjustment software
Adjustable calibration reminder function
|
Wall-display humidity meters
|
|
|
|
TST0468-623 HYGROMETER WITH HISTORY FUNCTION OF THE MEASUREMENT VALUES,
|
|
Hanging and standing bracket allows felxible positioning on a wall or desktop
Analysis of past temperature and humidity values directly on site without evaluation on a PC
All important values at a glance: current and past temperature and humidity values as well as date and time
|
Wall-display humidity meters
|
|
|
|
TST0189/190 - Wall Display Thermo-Hygrometer with/without alarm with Resolution 0.1 deg.c
|
|
The accurate TST0189/190 alarm hygrometer reliably indicates when humidity and temperature limits have been exceeded, for example in garden centres, warehouses, cleanrooms, museums, laboratories etc.
All the benefits of TST0189
High accuracy ±2 %RH (TST0190)
TST0190 with LED alarm, warns if limits are exceeded
Storage temperature -40 to +70 °C Operating temperature -10 to +70 °C Battery type 9V block battery Battery life 8736 h Weight 168 g Material/Housing ABS
Probe... |
Wall-display humidity meters
|
|
|
|
TEN810-Datalogging Large Wall Display Temperature /Humidity Monitor with 95dB Sound Alarm/Controller
|
|
Complete environmental monitor and alarm - Wall-Mounted LED type, easy reading - Alarm set for Hi and Low limit-Temperature and Humidity - Data Logging Capacity 30,000 records - LED displays real time data - USB interface- XL Display: 260 x 178 x 47mm- High Accuracy and high sensitivity
|
Wall-display humidity meters
|
|
|
|
TST106-635+TST0264 Germany Advanced ThermoHygrometer (max +140c)
|
|
Storage temperature
-30 to +70 °C
Operating temperature
-20 to +50 °C
Battery type
Alkali manganese, mignon, Type AA
Battery life
200 h
Weight
428 g
Dimensions
220 x 74 x 46 mm
Material/Housing
ABS/TPE/Metal
Probe - Typ T (Cu-CuNi)
Meas. range
-200 to +400 °C
Accuracy
±0.3 °C (-60 to +60 °C)
±0.5% of mv (remaining... |
Portable humidity meters
|
|
|
|
TST0103-625 COMPLETE HUMIDITY/TEMPERATURE MEASURING INSTRUMENT COMPLETE W/ CONNECTION CABLE & CASE
|
|
humidity/temperature instrument, incl. plug-in humidity probe head, battery and calibration document
Displays temperature and relative humidity / wet bulb temperature / dewpoint
Max./min. values
Hold button to freeze readings
Display light
|
Portable humidity meters
|
|
|
|
TES0051-1362 PRINTING HUMIDITY TEMPERATURE METER
|
|
* Triple LCD Display for RH% Humidity, T1 for Air Temperature and T2 Type K Thermometer (-200 ℃ ~ 1333 ℃ ). * Dew Point Reading. * Max / Min / Data Hold. * Real Time Stamp. * Periodically Print out from Pre-Set time Interval.
Measuring Range
T1 : Temperature : - 20 ℃ ~ 60 ℃ (- 4 ℉ ~ 140 ℉ ) Humidity : 10%RH ~ 95%RH T2 : Type K : - 200 ~ 1333 ℃ (- 58 ~ 2431 ℉ )
Resolution
0.1 ℃ /0.1 ℉ /0.1%RH
Accuracy
T1 : Temperature : +/- 0.8 ℃ , +/- 1.5 ℉ Humidity... |
Portable humidity meters
|
|
|
|
TES0050 - 1360 Humidity/Temperature Meter
|
|
Laboratory
Quality Control
Air-Conditioning
Process Engineering
Range: Humidity
10% to 95% R.H.
Temperature
-20 ℃ to +60 ℃ ; -4 o F to +140 ℉
Resolution
0.1% R.H. 0.1 ℃ , 0.1 ℉
Accuracy (after calibration)
Humidity
+/ - 3% R.H. (at 25 ℃ , 30...95% R.H.)
Temperature
+/ - 0.8 ℃ , +/ - 1.5 ℉
Response time
Humidity
45% R.H. --> 95% R.H. < = 3min 95% R.H. -->... |
Portable humidity meters
|
|
|
|
TST0102-610 Humidity and temperature measuring instrument
|
|
Humidity and temperature measuring instrument incl. protective cap, batteries and calibration protocol
TST0102 measures relative air moisture and temperature simultaneously. Dew point calculation and wet bulb as well as Hold function and max./min. display are possible with this instrument.
Long-term stable Testo humidity sensor
+/-2.5 %RH accuracy
Incl. calibration protocol
Dewpoint calculation and wet bulb included
Hold function and max./min. values
Protective cap for safe... |
Portable humidity meters
|
|
|
|
TST0103-625 COMPLETE HUMIDITY/TEMPERATURE MEASURING INSTRUMENT COMPLETE WITH CONNECTION CABLE
|
|
Displays temperature and relative humidity / wet bulb temperature / dewpoint
Max./min. values
Hold button to freeze readings
Display light
Auto Off function
TopSafe, the indestructible protection case (optional)
Patented humidity sensor
2 year guaranteed long-term stability
TopSafe, instrument protection against dirt and knocks (optional)
Go for TST0191 if you do not need a cable
|
Portable humidity meters
|
|