Tenmars TM-27E AC/DC True RMS Model No.: : TM-27E Product Description CAT III 600V 3-3/4 digit LCD, Backlit Display with maximum reading of 4000. True-Rms. Data Hold, Min/Max, functions. AC/DC volts, AC/DC current, Resistance, Frequency, Continuity. Autoranging. Relative (REL) zero adjust. Maximum conductor size 35mm. Low battery indication. Overload indication. Continuity buzzer. Auto power off. Clamp Meter
Tenmars TM-13E_AC/DC Clamp Meter Model No.: : TM-13E Product Description CAT III 600V 3-3/4 digit LCD with Analog Bargraph. Display Counts: 4000. Low battery indication. Auto Ranging. Data Hold and Range Hold Auto Zero. Test Ranges: ACV, ACA, DCV, DCA, Resistance, Continuity. Maximum conductor size 30mm. Continuity test below 40 ohms, buzzer will sound. Auto Power off. Clamp Meter
Tenmars TM-28E_TRMS AC/DC WATT Clamp Meter Model No.: : TM-28E Product Description CAT III 600V 3-3/4 digit LCD, Backlit Display with maximum reading of 4000. High-speed bargraph. True-Rms. Watt measurement: 400KW Data Hold, Peak Hold, Min/Max, and Zero functions. AC/DC volts, AC/DC current, Resistance, Frequency, Watts, Continuity. Autoranging. Relative (REL) zero adjust. Maximum conductor size 35mm. Low battery indication. Overload indication. Continuity buzzer. Auto power off. Clamp Meter
Tenmars TM-1016 AC-HVAC Clamp Meter Model No.: : TM-1016 Product Description CAT III 600V 3-3/4 digit LCD Backlit Display, with Analog Bargraph. Display Counts: 4000. Auto Ranging. AC/DC current: 0.1µA to 4000µA. (using test leads). AC current: 0.01A to 400A (using jaw measurement). Ranges: ACV, ACA, DCV, DCA, Resistance, Continuity, Capacitance, and Temperature. Maximum conductor size 30mm. Continuity test below 40 ohms, buzzer will sound. Auto Power off. Double injection outer case. Clamp Meter
Tenmars TM-1017 400A True-RMS AC Power Clamp Meter + Phase Rotation Model No.: : TM-1017 Product Description CAT III 600V Maximum conductor size 30mm. Display counts: 4000. Measures: ACV, DCV, ACA. Measures Phase Sequence. Voltage/Current Harmonics to 25th with THD. W3ø, HV, HA, Phase SEQ, Audible continuity tests. Frequency to 400Hz. Active, Reactive, Apparent power/ energy on. Power Factor, cosø on Single/Three phase systems. Phase sequence. Clamp Meter
Tenmars TM-2011 AC Clamp Meter Model No.: : TM-2011 Product Description CAT IV 600V, CAT III 1000V 3-3/4 digit LCD backlit display and bargraph, with maximum reading of 4000. AC voltage range: 0 to 750V. AC current range: 0 to 660A. DC voltage range: 0 to 1000V. Resistance measurement to 4000 ohms. Data Hold, Peak Hold, Min/Max, Autoranging. Test Ranges: ACV, ACA, Resistance, Frequency, Diode, Continuity. Work light. Low battery indication. Clamp Meter
Tenmars TM-2013 TRMS AC/DC Clamp meter Model No.: : TM-2013 Product Description CAT IV 600V, CAT III 1000V LCD backlit display, with maximum reading of 6600. AC voltage range: 0 to 750V. AC current range: 0 to 660A. DC voltage range: 0 to 1000V. DC Current: 0 to 660A. Resistance measurement to 66 megohms. Data Hold, Min/Max, Autoranging, DCA Zero. Test Ranges: ACV, ACA, Resistance, Frequency, Diode, Continuity. Work light. Auto Power Off. Double Injection outer case. Clamp Meter
Tenmars TM-3011_AC Clamp Meter Model No.: : TM-3011 Product Description CAT IV 600V, CAT III 1000V 3-3/4 digit LCD Backlit display with maximum reading of 4000. Analog Bargraph. AC voltage range: 0 to 750V. AC current range: 0 to 1200A. Peak Hold, Data Hold, Min/Max. Test Ranges: ACV, ACA, DCV, Resistance, Frequency, Diode, Continuity. Work Light. Auto Power Off. Double injection outer case. Clamp Meter
Tenmars TM-3014 AC/DC Clamp Meter Model No.: : TM-3014 Product Description CAT IV 600V, CAT III 1000V LCD Backlit display with maximum reading of 6600. AC voltage range: 0 to 750V. AC current range: 0 to 1200A. DC voltage range: 0 to 1000V. DC current range: 0 to 1200A Data Hold, Min/Max, Inrush. Test Ranges: ACV, ACA, DCV, DCA, Resistance, Frequency, Diode, Capacitance, Continuity. Work Light. Auto Power Off. Double injection outer case. Clamp Meter
Tenmars TM-3013 AC/DC Clamp Meter Model No.: : TM-3013 Product Description CAT IV 600V, CAT III 1000V 3-3/4 digit LCD Backlit display with maximum reading of 4000. Analog Bargraph. AC voltage range: 0 to 750V. AC current range: 0 to 1200A. DC voltage range: 0 to 1000V. DC current range: 0 to 1200A Peak Hold, Data Hold, Min/Max. Test Ranges: ACV, ACA, DCV, DCA, Resistance, Frequency, Diode, Continuity. Work Light. Auto Power Off. Double injection outer case. Clamp Meter
Tenmars YF-80 Phase Rotation Tester Model No.: : YF-80 Product Description • Detect the phase sequence (R-S-T) of 3-phase circuit • Electronic circuit configuration allows more specific function display • Automated detection for low-battery capacity 3 Phase/ Motor Rotation Tester
Tenmars TM-604 3 Phase/ Motor Rotation Tester Model No.: : TM-604 Product Description Display by LED indicators. Inter-phase voltage: 45V AC up to 600V AC. Signal Frequency Range: 45Hz to 400Hz. Test Currents inter-phase less than 3.5mA. Two UL 500mA/700V fuse protection. Low battery detection. 3 Phase/ Motor Rotation Tester
Tenmars TM-601N 3 Phase/ Motor Rotation Tester Model No.: : TM-601N Product Description Waterproof Phase/Motor Rotation Tester EN 61010-1 CAT III 1000V, CAT IV 600V, EN 61557-7 Display by LED indicators. Inter-phase voltage: 45V AC up to 600V AC. Signal Frequency Range: 45Hz to 400Hz. Test Currents inter-phase less than 3.5mA. Two UL 500mA/700V fuse protection. Low battery detection. Waterproof resist. 3 Phase/ Motor Rotation Tester
Tenmars YF-150 Capacitance Meter Model No.: : YF-150 Product Description • Display: 3 1/2 digital with 0.86"(22mm) LCD • Range: 0.1pF~20mF (20000uF) • Stalls and accuracy: 200P ± (0.5% rdg +1 dgt +0.5 pF) 2000P/20n/200n/2u/20u/200u ± (0.5% rdg +3 dgt) 20MF ± (2% +1 dgt) • Accuracy: 0.5% / auto-zero function • Overload fuse protection • Compact form factor, with a bracket • Volume: 143 (L) × 74 (W) × 39 (H) mm Capacitance Meter
TOKOGAWA AQ2212 FRAME CONTROLLER (9 SLOTS) The AQ2211 and AQ2212 frame controllers are platforms for the AQ2200 Multi Application Test System. These frame controllers contain a variety of measurement applications that enable you to get the information you need without connecting an external controller PC. In addition, they have three different external interfaces, so you can always use the best interface for a particular measurement application. Easy-to-view color display USB port for data storage Measurement module "hot-swapping"... MODULAR MANUFACTURING TEST SYSTEM
TST0087-512-9 0-2000hpa manometer - Germany differential pressure meter, 0 to 2000 hPa, incl. battery and calibration protocol 8 switchable units of pressure: kPa, hPa, Pa, mm H2O, mmHg, psi, inch H2O, inch Hg Integrated density compensation Display illumination Hold-/max-/min function Printout of measurement values incl. date/time and min/max values Storage temperature -10 to +70 °C Operating temperature 0 to +60 °C Battery type 9V block battery, 6F22 Battery life 120 h Weight 300 g Dimensions 202 x... Manometer/Differential pressure meters
TST0080/81 0-100 mbar manometer - Germany Features: Measuring range: 0 to 100 mbar Resolution: 0.01 mbar Selectable units:  differential manometer measures differential pressure in the range from 0 to 100 mbar. The pressure measurement is temperature compensated to obtain accurate measurement values. The measurement values can be displayed inPascal over the entire measurement range. Magnets at the rear of the instrument permit hand free operation. The backlit display allows the measurement values to... Manometer/Differential pressure meters