|
|
DKK-TOA TUF-1600
|
|
Suitable for water purification process (including river water, etc.)
Surface scattering light method employed; 1 range/2 ranges/3 ranges available
Reduces flow volume of sample water to 1/2 of existing models
RS-485 equipped as standard specification; compatible with Modbus communication system
Freely mountable on walls, racks, etc. for the compact lightweight design
Meas. range
0 - 2 to 0 - 2000 (1 - 3 ranges) (mg/L, ppm, FTU, NTU)
|
Turbidity Analyzer
|
|
|
|
DKK-TOA TUH-1600
|
|
High Sensitivity Turbidity Analyzer TUH-1600
Highly-sensitive turbidity analyzer suitable for water purification process
Surface scattering light method employed; 1 range/2 ranges/3 ranges available
RS-485 equipped as standard specification; compatible with Modbus communication system
Freely mountable on walls, racks, etc. for the compact lightweight design
Meas. range
0 - 0.2 to 0 - 2.0 (1 - 3 ranges) (NTU)
|
Turbidity Analyzer
|
|
|
|
DKK-TOA TUI-100
|
|
Turbidity Meter with Integrating Sphere TUI-100
Integrating sphere system employed for lab turbidity measurements
Continuous measurement of turbidity in tap water, river water, industrial water, etc.
Accurate results for minimized influence of color
Meas. range
0 - 0.5/5 to 0 - 100/1000 Cell length: 50mm or 10mm (selectable) (mg/L, ppm, FTU, NTU)
|
Turbidity Analyzer
|
|
|
|
DKK-TOA COL-110
|
|
Colorimeter/Turbidity Meter COL-110
Color and turbidity can be measured simultaneously by dual wavelength with just one meter
Equipped with interactive easy-to-use colortouch panel
Meas. range
Color: 0 - 10/20/30 (degrees C, DEG) Turbidity: 0 - 2/4/5/10 (degrees C, mg/L, ppm)
|
Turbidity Analyzer
|
|