DKK-TOA MWB4-70
|
|
B4 size compact analyzer excellent in reliability, durability and maintainability
Enables continuously measurement of turbidity, color, residual chlorine, pH, conductivity, temperature and pressure without reagents
Equipped with interactive easy-to-use color touch panel
|
Automatic Water Quality Analyzer for City Water
|
|
|
|
DKK-TOA CLF-1600
|
|
Measures residual chlorine (total or free) happened in the water chlorination process
Continuously measurement with polarographic method
1/5 reagent requirement of existing models
RS-485 equipped as standard specification; compatible with Modbus communication system
Freely mountable on walls, racks, etc. for the compact lightweight design
Meas. range
0 - 0.5/1.0 to 0 - 5/10 mg/L (ppm) (2-range)
|
Residual Chlorine Analyzer
|
|
|
|
DKK- TOA CLF-1610
|
|
Measures free residual chlorine of clean water continuously with the reagentless polarographic method
RS-485 equipped as standard specification; compatible with Modbus communication system
Freely mountable on walls, racks, etc. for the compact lightweight design
Meas. range
0 - 1/2, 0 - 1/3, 0 - 2/3 mg/L (ppm) (2-range)
|
Reagentless Free Chlorine Analyzer
|
|
|
|
DKK-TOA CD-36D/38D
|
|
Measures free residual chlorine of chlorinated samples from purification/food processing/semiconductor plants and pool without reagent
Continuous measurement by polarographic method
Meas. range
CD-36D: 0 - 2 mg/L (ppm) CD-38D: 0 - 100 mg/L (ppm)
|
Reagentless Free Chlorine Analyzer
|
|
|
|
DKK-TOA CLF-120
|
|
Reagentless Residual Chlorine Analyzer CLF-120
Measures total residual chlorine of drainage water without reagent
Continuous measurement by polarographic method
Meas. range
0 - 0.5/1.0, 0 - 1/2, 0 - 2/3 mg/L (ppm)
|
Reagentless Free Chlorine Analyzer
|
|
|
|
DKK-TOA CLBM-50
|
|
Residual Chlorine Analyzer CLBM-50
Ultracompact DIN 48 size
Reagenless model
Auto-cleaning by polishing beads and micro-vibrating electrode
Power supply: 100 - 230VAC
Low power consumption of 5VA
Meas. range
0 - 3 mg/L
|
Reagentless Free Chlorine Analyzer
|
|
|
|
DKK- TOA CLD-7M
|
|
Measures chloride demand of water and estimates chlorine injection level; best suited for feed forward control
Meas. range
From 0 - 5 mg/L to 10 mg/L (ppm) From 0 - 10 mg/L to 20 mg/L (ppm)
|
Chloride Demand Analyzer
|
|
|
|
DKK-TOA COL-110
|
|
Color and turbidity can be measured simultaneously by dual wavelength with just one meter
Equipped with interactive easy-to-use color touch panel
Meas. range
Color: 0 - 10/20/30 (degrees C, DEG) Turbidity: 0 - 2/4/5/10 (degrees C, mg/L, ppm) |
Colorimeter/Turbidity Meter
|
|
|
|
DKK-TOA TUF-1600
|
|
Suitable for water purification process (including river water, etc.)
Surface scattering light method employed; 1 range/2 ranges/3 ranges available
Reduces flow volume of sample water to 1/2 of existing models
RS-485 equipped as standard specification; compatible with Modbus communication system
Freely mountable on walls, racks, etc. for the compact lightweight design
Meas. range
0 - 2 to 0 - 2000 (1 - 3 ranges) (mg/L, ppm, FTU, NTU)
|
Turbidity Analyzer
|
|
|
|
DKK-TOA TUH-1600
|
|
High Sensitivity Turbidity Analyzer TUH-1600
Highly-sensitive turbidity analyzer suitable for water purification process
Surface scattering light method employed; 1 range/2 ranges/3 ranges available
RS-485 equipped as standard specification; compatible with Modbus communication system
Freely mountable on walls, racks, etc. for the compact lightweight design
Meas. range
0 - 0.2 to 0 - 2.0 (1 - 3 ranges) (NTU)
|
Turbidity Analyzer
|
|
|
|
DKK-TOA TUI-100
|
|
Turbidity Meter with Integrating Sphere TUI-100
Integrating sphere system employed for lab turbidity measurements
Continuous measurement of turbidity in tap water, river water, industrial water, etc.
Accurate results for minimized influence of color
Meas. range
0 - 0.5/5 to 0 - 100/1000 Cell length: 50mm or 10mm (selectable) (mg/L, ppm, FTU, NTU)
|
Turbidity Analyzer
|
|
|
|
DKK-TOA COL-110
|
|
Colorimeter/Turbidity Meter COL-110
Color and turbidity can be measured simultaneously by dual wavelength with just one meter
Equipped with interactive easy-to-use colortouch panel
Meas. range
Color: 0 - 10/20/30 (degrees C, DEG) Turbidity: 0 - 2/4/5/10 (degrees C, mg/L, ppm)
|
Turbidity Analyzer
|
|
|
|
DKK-TOA SSD-1610(For Low Concentration)/SSD-1620(For Medium Concentration)
|
|
Compact and piston automated analyzer
Types of detectors available: immersion, drop-in and pipe insertion
Long-life optical model and high reliability
RS-485 interface equipped as standard specification; compatible with Modbus communication system
Meas. range
SSD-1610: 0 - 30/500/1000 mg/L SSD-1620: 0 - 5000/10000/20000 mg/L (3-range, manual switching)
|
Suspended Solids Concentration Analyzer
|
|
|
|
DKK-TOA SSF-1600
|
|
Continuous optical measurements of SS and MLSS by using infrared scattering method
Safe and simple maintenance attainable with the small, lightweight stainless detector
Meas. range
0 - 1000/3000 mg/L 0 - 10000/20000/30000 mg/L (2-ranges or 3-ranges)
|
Suspended Solids Concentration Analyzer
|
|
|
|
DKK-TOA ALF-1600
|
|
Continuous measurement of alkalinity data in water purification process by coulometric titration method
Requires only 1/4 reagent volume of existing model
RS-485 equipped as standard specification; compatible with Modbus communication system
Freely mountable on walls, racks, etc. for the compact lightweight design
Meas. range
0 - 50/100 mg/L (ppm) (2-ranges)
|
Alkalinity Analyzer
|
|
|
|
DKK-TOA FS-3
|
|
The cleaning process done by two filters alternately allows for continuous supply of sample
Filtration rate
1 - 6 L/min (Varies from sample turbidity) |
Sand Filter
|
|
|
|
DKK-TOA BSC
|
|
A complete sampling system composed with cooler, pressure reducer, valves, flowmeter and thermostat chambers
Enables sampling for analysis from the boiler
Consistent manufacturing from analyzer to sampler
Sample condition
Maximum temperature: 600 degrees C Maximum pressure: 30 MPa Maximum flow rate: 3 L/min
|
Boiler Sampling System
|
|
|
|
DKK-TOA HYM-300
|
|
Continuous measurement of hydrazine concentration in boiler water
Stabilization determination function during calibration
Best suited for monitoring of residual hydrazine concentration
Meas. range
0 - 999.9 μg/L
|
Hydrazine Transmitter
|
|
|
|
DKK-TOA EMNA-10
|
|
Continuous measurement of Na+ ion concentration of boiler water at ppb level
Auto self-detection of degradation of ion-exchange system
Meas. range
0 - 0.1/1 - 100/10 - 1000 ppb (manual swtiching)
|
Sodium Ion Monitor
|
|
|
|
DKK-TOA BPM-2000
|
|
Designed for oil refinery
Automatic fractional distillate analyzer of batch distillation type enables distillation test of petroleum products such as kerosene, diesel oil, gasoline and etc.
Adopts high resolution liquid level detecting sensor
Newly-developed FA computer embedded with large-sized, color touch panel
Explosion-proof TIIS fd2G4 certified
Meas. range
Standard:Light gas oil (0 - 400 degrees C), Kerosene (0 - 300 degrees C), Gasoline (0 - 200degrees C)
|
Boiling Point Analyzer
|
|