DKK-TOA MWB4-70 B4 size compact analyzer excellent in reliability, durability and maintainability Enables continuously measurement of turbidity, color, residual chlorine, pH, conductivity, temperature and pressure without reagents Equipped with interactive easy-to-use color touch panel Automatic Water Quality Analyzer for City Water
DKK-TOA CLF-1600 Measures residual chlorine (total or free) happened in the water chlorination process Continuously measurement with polarographic method 1/5 reagent requirement of existing models RS-485 equipped as standard specification; compatible with Modbus communication system Freely mountable on walls, racks, etc. for the compact lightweight design Meas. range 0 - 0.5/1.0 to 0 - 5/10 mg/L (ppm) (2-range) Residual Chlorine Analyzer
DKK-TOA CLBM-50 Residual Chlorine Analyzer CLBM-50   Ultracompact DIN 48 size Reagenless model Auto-cleaning by polishing beads and micro-vibrating electrode Power supply: 100 - 230VAC Low power consumption of 5VA Meas. range 0 - 3 mg/L   Reagentless Free Chlorine Analyzer
DKK-TOA CLF-120 Reagentless Residual Chlorine Analyzer CLF-120   Measures total residual chlorine of drainage water without reagent Continuous measurement by polarographic method Meas. range 0 - 0.5/1.0, 0 - 1/2, 0 - 2/3 mg/L (ppm)   Reagentless Free Chlorine Analyzer
DKK-TOA CD-36D/38D Measures free residual chlorine of chlorinated samples from purification/food processing/semiconductor plants and pool without reagent Continuous measurement by polarographic method Meas. range CD-36D: 0 - 2 mg/L (ppm) CD-38D: 0 - 100 mg/L (ppm) Reagentless Free Chlorine Analyzer
DKK- TOA CLF-1610 Measures free residual chlorine of clean water continuously with the reagentless polarographic method RS-485 equipped as standard specification; compatible with Modbus communication system Freely mountable on walls, racks, etc. for the compact lightweight design Meas. range 0 - 1/2, 0 - 1/3, 0 - 2/3 mg/L (ppm) (2-range) Reagentless Free Chlorine Analyzer
DKK- TOA CLD-7M  Measures chloride demand of water and estimates chlorine injection level; best suited for feed forward control Meas. range From 0 - 5 mg/L to 10 mg/L (ppm) From 0 - 10 mg/L to 20 mg/L (ppm) Chloride Demand Analyzer
DKK-TOA COL-110 Color and turbidity can be measured simultaneously by dual wavelength with just one meter Equipped with interactive easy-to-use color touch panel Meas. range Color: 0 - 10/20/30 (degrees C, DEG) Turbidity: 0 - 2/4/5/10 (degrees C, mg/L, ppm) Colorimeter/Turbidity Meter
DKK-TOA COL-110 Colorimeter/Turbidity Meter COL-110   Color and turbidity can be measured simultaneously by dual wavelength with just one meter Equipped with interactive easy-to-use colortouch panel Meas. range Color: 0 - 10/20/30 (degrees C, DEG) Turbidity: 0 - 2/4/5/10 (degrees C, mg/L, ppm)   Turbidity Analyzer
DKK-TOA TUI-100 Turbidity Meter with Integrating Sphere TUI-100 Integrating sphere system employed for lab turbidity measurements Continuous measurement of turbidity in tap water, river water, industrial water, etc. Accurate results for minimized influence of color Meas. range 0 - 0.5/5 to 0 - 100/1000 Cell length: 50mm or 10mm (selectable) (mg/L, ppm, FTU, NTU) Turbidity Analyzer
DKK-TOA TUH-1600 High Sensitivity Turbidity Analyzer TUH-1600 Highly-sensitive turbidity analyzer suitable for water purification process Surface scattering light method employed; 1 range/2 ranges/3 ranges available RS-485 equipped as standard specification; compatible with Modbus communication system Freely mountable on walls, racks, etc. for the compact lightweight design Meas. range 0 - 0.2 to 0 - 2.0 (1 - 3 ranges) (NTU) Turbidity Analyzer
DKK-TOA TUF-1600 Suitable for water purification process (including river water, etc.) Surface scattering light method employed; 1 range/2 ranges/3 ranges available Reduces flow volume of sample water to 1/2 of existing models RS-485 equipped as standard specification; compatible with Modbus communication system Freely mountable on walls, racks, etc. for the compact lightweight design Meas. range 0 - 2 to 0 - 2000 (1 - 3 ranges) (mg/L, ppm, FTU, NTU) Turbidity Analyzer
DKK-TOA SSF-1600 Continuous optical measurements of SS and MLSS by using infrared scattering method Safe and simple maintenance attainable with the small, lightweight stainless detector     Meas. range 0 - 1000/3000 mg/L 0 - 10000/20000/30000 mg/L (2-ranges or 3-ranges) Suspended Solids Concentration Analyzer
DKK-TOA SSD-1610(For Low Concentration)/SSD-1620(For Medium Concentration) Compact and piston automated analyzer Types of detectors available: immersion, drop-in and pipe insertion Long-life optical model and high reliability RS-485 interface equipped as standard specification; compatible with Modbus communication system Meas. range SSD-1610: 0 - 30/500/1000 mg/L SSD-1620: 0 - 5000/10000/20000 mg/L (3-range, manual switching) Suspended Solids Concentration Analyzer
DKK-TOA ALF-1600 Continuous measurement of alkalinity data in water purification process by coulometric titration method Requires only 1/4 reagent volume of existing model RS-485 equipped as standard specification; compatible with Modbus communication system Freely mountable on walls, racks, etc. for the compact lightweight design Meas. range 0 - 50/100 mg/L (ppm) (2-ranges) Alkalinity Analyzer
DKK-TOA FS-3 The cleaning process done by two filters alternately allows for continuous supply of sample Filtration rate 1 - 6 L/min (Varies from sample turbidity) Sand Filter
DKK-TOA BSC A complete sampling system composed with cooler, pressure reducer, valves, flowmeter and thermostat chambers Enables sampling for analysis from the boiler Consistent manufacturing from analyzer to sampler Sample condition Maximum temperature: 600 degrees C Maximum pressure: 30 MPa Maximum flow rate: 3 L/min Boiler Sampling System
DKK-TOA HYM-300 Continuous measurement of hydrazine concentration in boiler water Stabilization determination function during calibration Best suited for monitoring of residual hydrazine concentration  Meas. range 0 - 999.9 μg/L Hydrazine Transmitter
DKK-TOA EMNA-10 Continuous measurement of Na+ ion concentration of boiler water at ppb level  Auto self-detection of degradation of ion-exchange system Meas. range 0 - 0.1/1 - 100/10 - 1000 ppb (manual swtiching) Sodium Ion Monitor
DKK-TOA BPM-2000 Designed for oil refinery  Automatic fractional distillate analyzer of batch distillation type enables distillation test of petroleum products such as kerosene, diesel oil, gasoline and etc. Adopts high resolution liquid level detecting sensor Newly-developed FA computer embedded with large-sized, color touch panel Explosion-proof TIIS fd2G4 certified Meas. range Standard:Light gas oil (0 - 400 degrees C), Kerosene (0 - 300 degrees C), Gasoline (0 - 200degrees C) Boiling Point Analyzer